old:140556 new: 103-2578 - Badger Meter United States Sales

BRAND Badger Meter
Product old:140556 new: 103-2578
Description Liquid flow meter
Internal code ONR4835168
Weight 13.1
Custom code 9028 20 00
Technical specification RCDL M170 NPT inside 2" 643 l/min PPO Buna PM 5 1PPL made of bronze RCDL M170, with PM 5 1 Imp pulse generator /liter Materials and technical data: Case: bronze Measurement chamber: PPO O-rings: Buna Measurement range: 8-643 l/min Measurement accuracy: +/- 1.5% of the value p-max: 16 bar T-max: 50°C Connections: 2" NPT inside Installation length: 387 mm Installation position: horizontal, standing Pulse output: 1 pulse/liter, through reed switch, potential-free

Please Contact Us to Order to offer best price and delivery time for Badger Meter - old:140556 new: 103-2578 Liquid flow meter number, also you may ask some other model number is well. We can offer best price, and delivery time with wide products distribution network in United States Industrial products Market. 

WE SELL ONLY ORIGINAL AND NEW PRODUCTS!

Our company is not an authorized distributor and manufacturer's representative of the brands shown on the website. Private brand names shown on this site and trademarks are the property of their respective owners

Important note: Although we Badger Meter - Products are Onrion LLC not an authorized dealer. All rights are reserved by the manufacturers and their official partners. 

Where can I buy old:140556 new: 103-2578 by Badger Meter in United States?

You can purchase old:140556 new: 103-2578 by Badger Meter from Onrion LLC. We serve customers across United States, offering competitive prices and reliable service.

What is the price of the old:140556 new: 103-2578?

For customized pricing and availability, please fill out our contact form or give us a call. We are dedicated to providing solutions that align with your specific requirements.

Who is the official distributor or seller of Badger Meter in United States?

While we are not the official distributor or seller of Badger Meter in United States, we source our products from reliable channels and offer you original Badger Meter equipment at competitive prices.

How can I access old:140556 new: 103-2578 catalogs, user manuals, technical documents, and PDFs?

You can access catalogs, user manuals, and technical documents for old:140556 new: 103-2578 on our website. Visit our resources section or contact us directly for specific documents.

Do you provide technical support for old:140556 new: 103-2578?

While we do not offer direct technical support, we can assist you in contacting the manufacturer to ensure you receive the support you need.

More products of Badger Meter

LIQUID FLOW METER RCDL M70, WITH PULSE GENERATOR PFT-1E.

Body: Bronze Measuring chamber: Vectra O-rings: Viton Measuring range: 18 - 265 l / min Accuracy: + / - 1.5% of the value p-max: 16 bar t-max: 120 ° C Connection: R 1 1/4 "male Length: 273 mm Mounting position: horizontal, vertical Pulse Output: Transistor NPN open Scale Factor: 0.00001 to 0.9999 Supply: 12-24 VDC

LM OG-CND 

for petrol, oil, digital and electronic counters, rotary platforms ½, flow. 0-28 I / min

LM OG-PND P114

Product preset Max 120°F/50°C Min 20°F/-5°C 868 mhz

B102101

Einbauzähler mit Impulsgeber für Schmieröl

M2000 AM DN50

ELECTROMAGNETIC FLOW METER

MAGNETOFLOW TYP II DN 65 / PN 16

Magnetic flowmeter with transmitter M1500 for full pipes.

MID 2-100/16-F/ST-WG-ML/HC-ST M15A SK1

Type II DN 100 / PN 16 with amplifier M1500 for full pipes

MID M 1000 MIT FLANSCH DN 32 HARTGUMMI HASTELLOY C 24VDC

Magnetic flowmeter Magneto Flow Type II DN 32 / PN 16 with transmitter for M2000 full pipes.

MN7

schetchik jidkosti

MN80AAP-1

MN SERİES,70-733 LPM 1200 KPA 3”/80MM BSP

MODEL RCDL M25

BADGER METER RCDL DISC METERS POSITIVE DISPLACEMENT – NUTATING DISC

RCDL LCR

Register with pulse output, Electronic counter LCR type with an LCD display and, pulse output above for OG-Baureihe.Anzeige 1: resettable totalizer or flow indication programmable, Format xxxx.x. Display 2: Non-resettable totalizer, 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64 For counter Size: M25-M35-M40-M70-M120-M170 Pulse output: NPN, MOSFET 40V / 2A Pulse factor: 0.01-99.99 Pulse length: 10ms (2ms, 20ms, 40ms) Ext.Stromversorg. : 8-24VDC Pulse output PPL: 0,01-0,1-1-10-100 Dosing control: 0.01 to 999.99 Preliminary circuit: from 0.00 to 99.99 Switching output: NPN, MOSFET 40V / 2A

RCDL LCR REGISTER MIT IMPULSAUSGANG U. STROMAUSGANG 4-20MA

Electronic counter LCR type with an LCD display, Display 1: resettable totalizer or Flow display programmable, Format xxx.xx. Display 2: Non-resettable totalizer 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA

RCDL LCR REGISTER OHNE IMPULSAUSGANG

Electronic counter LCR type with an LCD display, for the OG series Display 1: resettable totalizer or Flow display programmable, format xxxx.x Display 2: Non-resettable totalizer 14 digits Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64

RCDL M25

3/4 "or 1" PPO Viton without pulse, fluid meter RCDL M25 without construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, standing

RCDL M25 1"

Vectra Viton pulse PFT-2 reed contact Liquid meter RCDL M25 without construction. Materials and technical data: Housing: Bronze Measuring chamber: Vectra O-rings: Viton Measuring range: 3-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: ° C Connection: R 1 "outside Installation length: 190 mm Installation position: horizontal, standing 604011 Pulse PFT-2 reed contact about 52 PPL

RCDL M25 3/4" ODER 1" PPO VITON OHNE IMPULSGEBER

(Liquid meter RCDL M25 without Construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, vertical)

RCDL M25, WITH PULSE- TRANSMITTER PFT-1E - 52,4 PULSE/LITER SETUP

Housing : Bronze Chamber : Noryl (PPO) O-Rings : Buna Flowrange : 1-100 l/min Accuracy : +/- 1,5 % of value p-max : 10 bar t-max : 50 °C Connection : Threads 1" male Laylength : 190mm Pulsoutput : Open Collector NPN Scale Factor : 0.00001 to 0.9999 Supply : 12-24 VDC Pulsoutput : S/N : Part-Nr. 141158

KT M2000 50

MID M 2000 mit Flansch DN 50 1.4571

106126

Oval wheel counter

PN : MID M 1000, Type : Typ ModMAG M1000

magnetic inductive flowmeter

7500P

Electromagnetic Flow Meter

XMT-DS-00738